Acid & Alkali Resistant Corrosion Resistance Chemical Lab Fume Hood Explosion Proof

Acid & Alkali Resistant Corrosion Resistance Chemical Lab Fume Hood Explosion Proof

Package Size 1900.00cm * 900.00cm * 2100.00cm Package Gross Weight 500.000kg 1. Product Description Fume hoods are an in
SHARE

Description

Basic Info.
Model NO. YH-1800A / YH-1800B / YH-1800C
Feature Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type Standard
Color Blue
Customized Customized
Condition New
Liner Ceramic Fiber
Sash Tempered Glass
Airflow Ceramic Fiber
Work Surface Ceramic
Baffle Ceramic
Product Name Fume Hood
Transport Package Standard Export Wooden Case Packing
Specification 1500*1205*2400(mm)
Trademark Ample
Origin Chengdu, China
HS Code 8414809090
Production Capacity 100 Set/Month
Packaging & Delivery
Package Size 1900.00cm * 900.00cm * 2100.00cm Package Gross Weight 500.000kg
Product Description
1. Product Description

Fume hoods are an integral part of most labs. These ventilated enclosures enable laboratory personnel to safely work with materials that produce hazardous fumes and volatile vapors. Selecting a fume hood that is the right fit for your laboratory is important and there are many different ducted and ductless designs to choose from. Traditionally, fume hoods consume large amounts of energy, but many newer units are designed with energy efficiency in mind, which reduces operating costs while providing the necessary protection.

    Product features:

    1. Easy to assemble; Anti-corrosion and high temperature resistance;2. Unique down return air, timely and effectively exhaust without residual;3. Special flow-equalized design makes the flow even without any blind angle;4. The internal visual range will not form condensate due to temperature difference, therefore no drip will form;5. The internal airflow direction is not affected by the volume of the exhaust air, thus will not cause turbulence;6. Low energy consumption, easy to operate;7. Has air compensation channel and connection, saves energy, comfortable;8. Drainage will not be limited by the height of the drain,since it has pump to lift the sewage;;

    Product function:1. Exhaust waste gas;2. New air compensation;3. Inorganic exhaust gas purification;4. Sewage treatment function (Acid and alkali neutralization);5. All electrical and mechanical devices can start and stop independently;6. Purification system resistance monitoring: auto-alarm when the set value is exceeded;7. Purification system temperature monitoring: auto-alarm when the set value is exceeded, and automatically cut offthe outlet power;8. Auto-monitoring the level of acid, alkali and spray media;9. Manual add acid and alkali (via dosing pump);10. Manual discharge of sewage (via sewage pump) and cleaning of spray system (via spray pump);11. Auto-replenishment of tap-water (via feed-water valve);12. Provide safe power supply (including phase-out and phase-sequence protection, Emergency power cuts, Leakage protection,Main power control;13. Safe light source (including adjustable white and non-UV yellow LED lights), external isolate installation;14. Water shortage protection for sewage pump and spray pump; 15. Overheat protection for mechanical andelectrical equipment;16. Alarm when sliding door in extra high position;17. The exhaust air volume is controlled by electric regulating valve;18. Other functions: water supply terminal, gas supply terminal and other experimental equipment can be installed according tocustomers' demands.
    2. Product Parameters
    Model SpecificationWJ-1500AWJ-1500BWJ-1800AWJ-1800B
    External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
    Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
    Panel material20+6mm thick butterfly ceramics
    Material of internal lining board5mm thick ceramic fiber board
    Diversion structureLower air return
    Control systemButton control panel (LCD panel)
    PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
    Input powerThree-phase five-wire 380V/50A
    Current for air fanNot over 2.8A(380V or 220V can be directly connected)
    Maximum load of socket12 KW(total of 4 sockets)
    Water tap1 set (remote control valve + water nozzle)No1 set (remote control valve + water nozzle)No
    Water discharge wayMagnetic chemical pump strong discharge
    Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
    Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
    Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
    Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
    Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
    Speed deviation of surface airNot higher than 10%
    The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
    NoiseWithin 55 decibels
    Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
    Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
    Resistance of exhaust cabinetLess than 160 pa
    Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
    Water consumptionLess than 3.2L/ hLess than 4.0L/ h
    Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
    Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)

    3. Type of Fume Hood

    Laboratory fume hoods can be fabricated from different materials and include specific surface types, such as stainless steel, fiberglass, PVC or even polypropylene.

    Chemical fume hoods are a mainstay for most research and educational labs. They protect users from chemical and radiological exposure. Ideal if you plan on conducting experiments that use toxic or volatile chemicals to lower the chances of inhalation.

    Laminar flow hoods protect the samples from contamination. They do not offer lab personnel any protection; thus, you must not use them when working with toxic or infectious chemicals.

    Demonstration or educational hoods: These are optimized for teaching. An example is the double-faced fume hoods, which have entrances on both sides, allowing for 360-degree viewing.

    Biological Safety Cabinets (BSCs) have a different application and do not fall within the fume hood category. They are, however, a must-have for labs that handle viral microbes and infectious diseases.4. Detailed Photos

    5. FAQ

    How to Choose the Right Size for Your Fume Hood Blower

    Next, you'll need to decide what size you'll need for your operations. This refers to the power of the fume hood blower and is essential to ensuring your equipment transfers enough air to keep your lab free of contamination.

    It's worth noting that choosing the most robust blower is not immediately the best option. If a blower is too powerful, it could strain the ductwork and create turbulence.

    Calculating the required power isn't easy. You'll need to consider the static pressure present in your duct system. This is calculated based on the diameter, duct length, number of bends, and velocity at which the fume will operate.

    Talk to your manufacturer or reach out to CFI and consult a fume hood expert for the right choice.

    How Many Operating Speeds Does Your Blower Need?

    Exhausting tempered air from your fume hood is often one of the most costly energy uses for laboratories.

    That's why depending on your operations, you might benefit from a blower with multiple speed settings that will allow you to alleviate the burden of these costs.

    Intelli-sense multi-speed blowers can operate at up to three speeds which are programmed through a control box. This is located on top of the hood.

    A blower with this function is very versatile. It could operate at lower speeds during the night, using the least amount of air. More extensive labs that operate on a constant volume can instead use belt-driven single-speed blowers.

    The Right Material for Your Exhaust System

    To ensure a safe exhaust system, you need to consider the correct material for your ductwork.

    Your ducting should be compatible with local fire codes. Most importantly, make sure it's compatible with the chemicals it will be exposed to in your lab. Most commonly, duct systems will be fashioned from:

    • PVC: This is intended for use with corrosives.
    • 316 Stainless Steel: Suitable for use with solvents.

    6. What Type of Fume Hood Fan or Blower Do You Need?

    Which type of blower you need depends on the intended use. If you are venting non-toxic materials, for example, you could use a steel blower coated with epoxy.

    If the purpose is to mix acids, you will need an acid-resistant blower. PVC is often the best material choice for perchloric acids and other corrosive operations.

    Where the chemicals in your lab are moderately or highly corrosive, fiberglass is also a good option. If your work is volatile, there are even blowers with explosion-proofing and those that are resistant to sparks.

    These fume hood blowers will often come with an enclosed motor that ensures fumes in the air stream won't encounter a spark or touch the motor.

    If there's any chance of fumes in your lab catching on fire, spark resistance should prioritize.